0800 088 6248 Get a price

How often should a roller shutter be serviced?

No law sets a service interval for a roller shutter. The Workplace Regulations 1992 require it to be maintained in efficient working order, and DHF guidance says the safety functions of a powered door should be tested at least annually. Start with the manufacturer's manual, then plan around how hard the shutter works.

Engineer on a step ladder servicing an open shutter box above a shop entrance

Is roller shutter maintenance a legal requirement for UK businesses?

Yes, the duty to maintain is a legal one, though the law sets no interval. Regulation 5 of the Workplace (Health, Safety and Welfare) Regulations 1992 requires workplaces, and the equipment and devices in them, to be maintained in efficient working order and in good repair.

HSE names these regulations, and section 3 of the Health and Safety at Work etc. Act 1974, as applying to commercial owners and occupiers of powered gates. HSE's general material groups powered doors and gates together and does not mention shop shutters by name, but the same thinking is likely to apply to a powered shop shutter.

This guide covers England and is general guidance, not legal advice.

How often should a roller shutter be serviced?

At least once a year is the sensible baseline for a powered shutter, because that is how often the safety functions should be tested. The law itself gives no figure. DHF's code of practice says "the law does not specify a particular maintenance period".

A shutter that runs many times a day, or one on a salty or dusty site, may need more. Six-monthly visits are common in maintenance contracts, but that is contract practice and not law. Take your frequency from the manufacturer's manual first, then adjust for how the shutter is used.

Use matters more than the calendar. A shutter that runs once a day on a quiet parade and one that opens for deliveries all day do not wear at the same rate. Springs and motors have a working life measured in cycles, so ask what yours is built for.

SourceWhat it saysStatus
Workplace Regulations, reg 5Keep it in efficient working orderLaw, no interval given
Workplace Regulations, reg 18Safety devices on doors and gatesLaw, no interval given
Manufacturer's manualThe service frequency for that shutterYour first reference
DHF code of practiceTest safety functions at least annuallyTrade guidance
Six-monthly contractPlanned visits twice a yearContract practice

What does regulation 18 say about shutters?

It sets 3 requirements that matter on a shutter. Regulation 18 says upward-opening doors must have a device that stops them falling back. Powered doors must have features that prevent trapping. They must also be able to be operated manually where that is needed for safety.

In shop terms: the safety brake must hold, the safety edge or other protection must work, and staff must know how to use the manual override. A service should test all 3, and our £145 check does not cover all of them, so see what it includes below or ask us. A manual shutter has no motor to trap anyone, but the fall-back rule still applies to it.

What is the DHF annual safety test?

It is a check of the safety functions on a powered door, at least once a year. DHF, the Door and Hardware Federation, says in TS 013-3 that hold-to-run, force limitation and presence detection "should be tested at least annually", with the manufacturer's manual as the first reference. Its publications list shows its codes of practice.

This is trade guidance and has no legal force in its own right. It is still the clearest benchmark available if anyone asks how you meet your duty.

What happens during a shutter service?

Our service and safety check costs £174 per shutter inc VAT (£145 plus VAT). It covers:

  • Spring tension.
  • Motor and limits.
  • Guides and laths.
  • Lubrication.
  • A safety brake test.
  • A written condition report.

Parts are quoted separately, and we confirm the cost before fitting anything. This is a paid call-out, often within the week. Ask the engineer to show your staff the manual override while they are there, because new staff rarely get shown it.

Do older shutters have to meet current standards?

Not automatically, but the duty to keep them safe still applies. HSE's safety bulletin says the revised standards for powered doors are not retrospective. It also says they do not fully meet the machinery requirements, so meeting them alone is not enough.

An old shutter is not unlawful simply for being old. If it has no anti-trap protection or the brake cannot be tested, though, you have a question to answer. We note any concerns on the report so you can decide what to do. Adding a motor to a manual shutter raises its own questions, so tell us before you convert one.

Who is responsible for servicing, the owner or the occupier?

Either can be, and your lease often decides who pays. Health and safety duties can rest on the occupier and on the person in control of the building, whatever the lease says about cost. Our guide on landlord and tenant repairs explains what to check. If you run several units, keep one list showing each shutter, who services it and when it was last done.

What should I check and record between services?

Have staff report any new noise, jerking, scraping or a curtain that runs crooked, and stop using the shutter until someone has looked at it. They can also check for loose guide fixings and a bottom rail that no longer sits flat. Our guide to a stuck roller shutter covers what is safe to touch.

Keep each dated service report, every repair invoice and the manufacturer's manual. No rule we found sets a format, but the file will show that you took the duty seriously. It also helps with your insurer, your landlord and any future engineer. See our guide to insurance and shutters for why this matters at claim time.

Common questions

Do manual shutters need servicing?

Yes, though the safety checks differ. A manual shutter still needs its spring balance, guides and fall-back protection checked, and regulation 5 still applies. Follow the manual.

Is a 6-monthly service a legal requirement?

No. It is a common contract practice. The law sets no interval, so base your plan on the manual and how often the shutter runs.

How much does a shutter service cost?

Our service and safety check costs £174 per shutter inc VAT (£145 plus VAT). Parts are quoted separately.

How do I book a service?

Use our fixed-price call-out page, or contact us. Servicing is a paid call-out, often within the week.

Do I get a certificate after a service?

You get a written condition report that records what we checked and found. Keep it with your maintenance records.

Sources

Related services

Find out what your frontage will cost

Free survey for new work across the Midlands, a written itemised quotation, and no obligation.

WhatsApp
Call usGet a price